TSIDMNT Commands CLOSE
Chapter 3. DSN Catalog Management Utility 3-19
CLOSE
BIM-EPIC only accesses active versions of a dataset. Datasets that are in “open” or
“conditionally cataloged” status cannot be processed, and they become eligible for scratch
differently from active versions. To access or save an open or conditionally cataloged dataset,
you must close it with the CLOSE command.
CLOSE only changes the DSN Catalog status of a version. It does not perform close
processing, such as writing tape or disk labels.
If an Automated Cartridge Library (ACL) is supported, CLOSE sets the tape volume to “non–
scratch” status in the ACL inventory.
CLOSE '
dataset-name
' [ ,SER=
volser
] [ ,GEN=
nnn
]
Parameter Required? Valid Default
dataset-name
Yes 1 to 44 characters None
SER No 1 to 6 characters None
GEN No 1 to 999999 None
dataset-name specifies the name of the dataset.
SER specifies the volume serial number of a tape version.
GEN specifies the generation number of a disk dataset.
If neither SER or GEN is specified, BIM-EPIC closes the most recently created version of
dataset-name.
The following example closes the BATCH.BALANCE dataset.
CLOSE 'BATCH.BALANCE'
Description
Syntax
Parameters
Example
Vista de pagina 128