Memorex LOCK - VERSION 2-24 Especificaciones Pagina 404

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 489
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 403
Selecting Datasets To Be Offloaded (TSIDOFD) Offload System
13-20 User Reference
REPORT specifies whether the Preliminary Dataset Selection Report is to be printed and
defaults to YES. This report shows the size of the internal selection table (in heading 2), the
selection criteria used, and the actual dataset versions selected.
CATALOG specifies whether selection should be for controlled disk datasets found in the
BIM-EPIC catalog or for controlled start-track-1 disk datasets. CATALOG=YES indicates
selection should be for controlled disk datasets found in the BIM-EPIC catalog and is the
default. CATALOG=NO indicates selection should be for controlled start-track-1 disk
datasets.
INCLUDE specifies that the datasets to be included for offload or backup are identified by the
subparameters that follow. At least one INCLUDE statement must be used.
OMIT specifies that the datasets to be omitted from offload or backup are identified by the
subparameters that follow. OMIT acts on datasets that have been included with an INCLUDE
statement.
POL selects datasets that are allocated to the specified pool. Up to 10 pool IDs can be
specified with INCLUDE, and for CATALOG=YES only, another 10 can be specified for
OMIT. You can specify multiple pool IDs on a single POL parameter
(POL=pool01,pool02,pool03...)
For CATALOG=YES, the POL parameter is checked against only the current pool name in
the dataset's definition. If that pool name has changed after a dataset version was created, you
must use other options to include or omit that dataset version.
For CATALOG=NO, the dataset must have been created using the specified pool name and
also satisfy all the following additional criteria:
SAM file
Prime Data extents
Reside completely within the current pool limits
NOT be defined in the BIM-EPIC catalog
Additionally for CATALOG=NO, datasets created by PIOCS programs (e.g., programs that
do not use Logical IOCS and also do not have an interface with BIM-EPIC) will NOT be
selected unless specifically requested using an INCLUDE control statement with a fully
qualified DSN parameter (i.e., without ‘.ALL’).
VOL selects datasets from the specified disk volume serial number. Up to 10 volume serial
numbers can be specified for INCLUDE, and another 10 can be specified for OMIT. You can
specify multiple volume serial numbers on a single VOL parameter (VOL=vol001, vol002,
vol003,...)
DSN selects a single dataset name or a set of datasets beginning with the same character
string. The value specified must be enclosed in apostrophes. To specify a group of datasets,
specify '.ALL' at the end of the dataset name.
VER selects a version number for a particular dataset. It can only be supplied if the DSN
parameter is also supplied. If omitted, all versions of the dataset are selected.
The following subparameters can be specified only once for INCLUDE and once for OMIT.
Vista de pagina 403
1 2 ... 399 400 401 402 403 404 405 406 407 408 409 ... 488 489

Comentarios a estos manuales

Sin comentarios