Activating and Deactivating BIM-EPIC Configuration Option Descriptions
Chapter 5. Activating and Deactivating BIM-EPIC 5-13
applies to output tapes. The value specified must be a number between 1 and 999. The
default is 10. Valid only with AUTOSTP=YES. If running under VM prior to VM/ESA, be
sure REALTIMER has been specified in the VM directory.
Related Configuration Options: AUTOSTP, AUTSTPN, AUTSTPNO, AUTSTPTO,
ERDFILE, TAPE
Determines the time interval (in seconds) between tape drive scans during AutoStop
processing when looking for an output tape. The value specified must be a number between 0
and 999. If AUTSTPTO=0 (the default) is specified, then AUTSTPTO defaults to using the
AUTSTPT value. If running under VM prior to VM/ESA, be sure REALTIMER has been
specified in the VM directory.
Related Configuration Options: AUTOSTP, AUTSTPN, AUTSTPNO, AUTSTPT,
ERDFILE, TAPE
Determines whether BIM-EPIC bypasses the DSN Catalog if a complete EXTENT statement
is specified.
If BYPEXT=YES, BIM-EPIC bypasses the DSN Catalog search at OPEN when you specify a
complete EXTENT for the file. It accesses the DSN Catalog only when there is no EXTENT
or when Start Track 1 datasets are used.
If BYPEXT=NO (the default), BIM-EPIC always accesses the DSN Catalog for disk files.
Related Configuration Options: AUTOCAT, DISKALL
Determines whether EP065 JOB CANCELLED is issued for cancelled jobs. EP065 requires
an operator response before EOJ processing can be completed, and ensures that Operations is
aware that the job was canceled.
If CANMSG=YES, EP065 is issued.
If CANMSG=NO (the default), EP065 is suppressed.
Related Messages: EP065
Determines whether Start Track 1 datasets are automatically cataloged. BIM-EPIC does not
issue EP023 for datasets cataloged in this manner.
If CATRT1=YES, Start Track 1 datasets are autocataloged. The dataset is defined as
WRK=YES. In addition, it specifies CYCL=0, unless you set EPS059 to YES which changes
it to CYCL=1. It also specifies RET=0, unless you set EPS062 to YES which changes it to
the value specified on the RETEN configuration option.
If you set CATRT1=YES, NCATDSK must be set to NO.
AUTSTPTO
BYPEXT
CANMSG
CATRT1