BIM-EPIC System Datasets Defining the Recorder File
Chapter 2. Installing the Basic System 2-21
Defining the Recorder File
The Recorder File can be shared among BIM-EPIC systems. However, it cannot be shared
with CA-EPIC for CMS systems.
Estimate the size of the Recorder File.
1. Determine the number of records to be logged each day. One record is logged for
each time a job starts or ends
each time a program starts or ends
each time an extent or reel of a cataloged dataset is opened or closed
each time the DSN Catalog is updated using Online Manager, TSIDMNT, or TSIDUTL
2. Use one of the following formulas to determine the amount of space to allocate:
For CKD tracks
R+4
4*B
For FBA blocks
R + 4
2
where R equals the estimated number of records to log each day.
B equals the number of blocks per track.
Use the following table to determine the value of B.
Device Type Number of Blocks
Per Track
3390 18
3380 18
3375 17
3350 7
3340 4
3330 5
9345-1 14
9345-2 21