Memorex RX 1 Smart Manual de instalación Pagina 188

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 262
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 187
Simrad MX500 | 187
LAN
RJ-45
Connector
LAN
RJ-45
Connector
1
2
3
4
5
6
7
8
1
6
7
4
5
6
7
8
Mx500
MASTER UNIT
Mx500
SLAVE UNIT
LAN TX +
LAN TX -
LAN RX +
NC
NC
LAN TX -
LAN TX +
NC
LAN RX +
LAN RX -
NC
LAN RX -
NC
NC
NC
NC
Cross-Over LAN Cable Diagram
Once the Dual Control IM is enabled, CFG1/Dual
Control screen looks like this:
DUAL CONTROL
Mode: Master (options: Master, Slave)
Dual Control: Yes (options: Yes, No)
GPS Source: Automatic (options: Automatic, Master,
Slave)
Integrity Alarm: Yes (options: Yes, No)
GPS Source: Master (options: Master, Slave)
Dual Status: OK (options: OK, No Comm, Mirroring)
To enable the functionality of the Dual Control
Integrity Monitoring, you must set the following to:
Dual Control: Yes
GPS Source: Automatic