Appendix B - Engineering mode | 147
Appendix B - Engineering Mode
The Engineering Display, which is activated in CFG1 Operation, enables an expanded
series of display screens in some of the functions. In general, these screens are used
by the technician during troubleshooting or by SIMRAD engineers during testing and
software debugging. This section describes what information is relevant to you, or the
information we need to help you troubleshoot your MX51x.
Information which is not described here is unsupported, which means SIMRAD will not
expand or provide any more information than what is provided in this manual.
If you should enable these screens, they will be turned off automatically the next time
power is cycled on the MX510.
AUX7 - Unit Information & Self Test
This screen indicates the software version, the hardware configuration, the printed
circuit board (PCB) serial number of the main board, the antenna model and software
version detected (if available) and AIS transponder (if available).
A special key sequence displays sub-version levels, the actual build date and allows
access to a selftest sequence. When the Engineering Display is active, the AUX7 screen
adds one line of detail to display the engineering level that is turned on:
MX510 AUX7 Screen MX512 AUX7 Screen
To access the Eng’g screens, press the EDIT key and #1 key three times. This will bring
up the Eng’g level to mode 3. Pressing the EDIT key will bring up softkeys that you use
to run a complete self test by highlighting the Make Selftest softkey then pressing ENT.
The first display of the self test is a keypad test. Press each function and softkey once.
When you have pressed each once the test will automatically advance to the Traffic Light
test. Observe that the three traffic lights go from dim to bright. Highlight the OK softkey
then press ENT if they illuminate correctly or Fail if they don’t.
The CDU will go on to conduct a Contrast test. Observe that the display goes through
its full range of contrast from white to black. Highlight OK then press ENT if it varies
correctly or Fail if it doesn’t. Next, the CDU will conduct a Backlight test. Observe that
the display goes through its full range of illumination. Highlight OK then press ENT if it
varies correctly or Fail if it doesn’t.