Here is a sample of the Brief format with an active route or MOB condition:
MX510 Navigator
====================================
21:24:00 UTC 11 Aug 1997
POS Mode : DGPS 3D Datum:W84
POS: N 33 48.5124 W 118 21.0213
COG: 152T SOG: 0.1 Kn
BRG: 239T Dist: 27.4 Nm XTE:0.14L Nm
RTE: RL From WPT 1234 To WPT 1357
-------------------------------------------------------------------------
Sending: Causes the printer output to be turned On or Off (default).
Print Interval (Sec): Allows you to control how often the print out will be sent to the
printer port. The default value is 60 seconds, and the valid range is from 1 to 9999
seconds.
Format: Allows you to choose either the Full or Brief formats described above.
Bit Rate: This allows you to control the port interface baud rate to match the printer or
computer you are interfacing with. The available baud rates are: 600, 1200, 2400,
4800 (default), 9600 or 19,200.
Data Bits: This allows you to match the printer’s requirement of 7 or 8 (default) bit serial
data.
Stop Bits: This allows you to match the printer’s requirement of 1 (default) or 2 stop bits.
Parity Check: This allows you to match the printer’s requirement of None (default), Even
or Odd parity.
Handshake: This allows you to match the printer’s requirement of No (default), XON/
XOFF or HW (Hardware; CTS, RTS ).
ROT (Rate of Turn)
The ROT configuration menu is available in the MX51x model. The “ROT connected”
mode can be toggled to YES or NO, by pressing the EDIT key and then highlighting the
Change’ softkey and press ENT.
Data input port no: 2 (valid port selections are 1,2, or 3*)
Alarm if no data: .. No (‘Yes’ value sets the alarm to sound if no ROT input data is
detected in 5 seconds)
*Use MX575 ROT: No
(Yes’ value would allow the MX51x to use ROT data from Port 3
when the MX575 is used as a positiong and heading device. ‘No’
value would allow the MX51x to use ROT data from any available
port other than Port 3 when the MX575 is used as a heading
device only (See MX575 Satellite Compass Installation and
Operation Manual for details).